Page 12 of 14
CONFIGURE GPIS FOR DRY/WET OPERATION
GPIs are set to Dry operation by default. The GPIs may be set for Wet mode
using either a Breakout Panel or using jumpers within the GC-32. To configure
the jumpers inside the GC-32:
1. Power down the GC-32 and then remove the top cover.
2. The jumpers for the GPIs are directly behind the GPI connectors, labeled
J7 through J38. Each set of jumpers for a GPI consists of 4 pins. See the
table below for which GPI corresponds to which jumpers.
3. For Dry operation, set one jumper across pins 2 and 3. Hang the second
jumper off of pin 1.
4. For Wet operation, set one jumper across pin 1 and 2. Set the second
jumper across pins 3 and 4.
5. Once all necessary changes to the jumpers have been made, replace the
top cover and power up the GC-32.
GPI
Jumper
GPI
Jumper
1 J7
17 J23
2 J8
18 J24
3 J9
19 J25
4 J10
20 J26
5 J11
21 J27
6 J12
22 J28
7 J13
23 J29
8 J14
24 J30
9 J15
25 J31
10 J16
26 J32
11 J17
27 J33
12 J18
28 J34
13 J19
29 J35
14 J20
30 J36
15 J21
31 J37
16 J22
32 J38
GPI ConnectorsGPO Connectors
J
7
J
2
2
J
2
3
J
3
8
Pin 1
Pin 2
Pin 3
Pin 4
Comentarios a estos manuales